Your Truma Combi will not heat, and the CP Plus shows a code such as E 517 H or W 255 H. What does it mean, and what can you do yourself?
Below are the error codes Truma publishes in its manuals and FAQ, with meaning and fix. Plus: how the codes are built, how to clear them and what to do with codes that appear in no list.
Quick answer
- W before the number is a warning: the heater keeps running. E is a fault. The H at the end stands for the heater.
- E 507 H, E 516 H, E 517 H: gas supply interrupted. Check the gas, then acknowledge the fault on the CP Plus.
- W 255 H: no connection between heater and control panel. Usually the heater has no 12 V.
- Acknowledging means: remove the cause, then press the rotary/push knob. Switching off and on does not clear a gas fault; it locks the heater for 15 minutes.
- If the code is flashing, a lockout period is running. It can only be reset after up to 15 minutes.
How Truma error codes are built
A code on the CP Plus has three parts, for example E 112 H:
- Letter in front: W for warning, E for fault. According to the Truma manual, the appliance keeps running during a warning and the warning symbol goes out by itself. With a fault, the CP Plus jumps straight to the “fault” menu level.
- Number: the actual error code.
- Letter at the end: the appliance. H stands for the heater, including the diesel Combi. A stands for the air conditioner, and on the Vario Heat E also stands for the E-Kit.
The codes often appear without spaces, such as E517H or W255H. They mean the same thing. Older Truma manuals write only the number with a hash, for example “#255”.
Two things are worth knowing before you look at the tables:
- Gas and diesel have separate lists. E 121 H means “flame unstable” on the gas Combi but “interruption in the dosing pump” on the Combi D.
- There are two generations on the gas Combi. The Truma FAQ separates the short codes (up to E 212 H) from the codes for the Combi gas built from 04/2018 (W 255 H and from W 301 H upwards). The current CP plus manual lists both in one table.
On the Truma iNet X Panel, a message first appears as plain text. According to Truma, you see the code via “More info …” or in the main menu via “>”.
How to acknowledge a fault, according to Truma
Acknowledging means confirming on the panel that the cause has been removed. The heater then restarts. According to the CP plus manual:
- Remove the cause, for example by connecting a full gas bottle.
- Press the rotary/push knob. If the display is in standby, the first press only switches on the backlight. The second press acknowledges the fault.
- Wait. The appliance restarts. Because of the after-run, this can take a few minutes. If there is a heating demand, the heater then starts by itself.
A warning (W) is selected via the warning symbol and confirmed with the knob. If you press the back button instead, the warning stays.
What Truma says to avoid:
- Switching the CP Plus off and on. With a gas fault, this does not clear the fault; it locks the heater for 15 minutes.
- Acknowledging again and again without removing the cause. After more than four resets within 15 minutes, the Combi gas locks with E 607 H.
- RESET → PR SET in the service menu. That is a device search, not a fault reset. More on this: Truma Combi reset: clearing faults, RESET on the CP Plus, reset button.
Flashing code: the heater is in a 15-minute lockout, for example after the control panel was switched off or the 12 V supply was interrupted. Leave the panel on and do not cut the power. After the lockout, the code is shown steadily and can be acknowledged as above.
These codes in detail
Truma has published its own help on these codes, or they are typical do-it-yourself cases.
E 507 H, E 516 H, E 517 H: gas supply interrupted
Combi gas: the heater gets no gas or detects no flame. Truma lists these causes:
- gas bottle empty
- gas bottle or quick-closing valve in the gas line closed
- gas pressure regulator iced up (Truma recommends a regulator heater, EisEx)
- too much butane: according to Truma, butane is unsuitable for heating, particularly below 10 °C. Use propane.
- combustion air inlet or exhaust outlet blocked, for example by slush, ice or leaves
- gas pressure regulator faulty
What to do: restore the gas supply, then acknowledge the fault with the knob. If the code is flashing, wait for the lockout to end. A faulty regulator is a job for a qualified gas engineer. If the fault keeps coming back with a full bottle, Truma’s service team says the heater belongs with a service partner.
W 255 H: no connection between heater and control panel
The CP Plus cannot reach the heater. According to Truma, the heater then has no 12 V, or the control panel cable is loose or faulty. The Truma FAQ names one everyday case explicitly: the heater’s 12 V was switched off on the vehicle’s own control panel, not on the Truma panel.
- Switch the 12 V supply back on at the vehicle’s control panel.
- Check that the control panel cable is firmly seated at the CP Plus and at the heater.
- Check the fuses in the vehicle’s power supply unit. Have the heater’s own fuse checked by a qualified person.
Once the cause has been removed, the warning disappears by itself, according to Truma. Important: no RESET → PR SET with W 255 H. If the CP Plus cannot find the heater during the device search, the heater menu is gone afterwards. Only the time and the setup symbol remain. For a Combi D with a very long control panel cable (over 12 m), Truma names a cable coupling as the remedy.
E 121 H: first check whether it is gas or diesel
- Combi gas: E 121 H belongs to the group E 112 H, E 121 H, E 122 H, E 202 H, E 211 H and E 212 H. Meaning according to Truma: flame out or not detected, flame unstable during operation, gas supply interrupted. Proceed as for E 517 H.
- Combi D (diesel): interruption in the dosing pump, a temperature switch has tripped. Truma says: clear the recirculation air intake, make sure the installation space is ventilated, use an altitude kit above 1500 m. Have cables, connectors and the dosing pump checked for a break.
E 122 H: on the Combi D, lack of fuel
Combi D 4, D 6 and the E versions (including the D 6 E): lack of fuel because there is little diesel in the tank, the tank has run dry or the vehicle is on a slope. According to Truma:
- Fill the tank and fill the fuel line as described for first use in the operating instructions.
- Make sure there are 12 V under load at the appliance.
- Above 1500 m, use an altitude kit and select the matching dosing pump.
Truma advises against running the tank down to the reserve mark. Each time it is switched on, the Combi D makes two start attempts of two minutes each. If no flame is detected, it goes into fault. According to the Combi D manual, 15 failed start attempts in total set a lock that only customer service can lift. The CP plus manual and the Truma supplement “Combi D error codes” give five acknowledgements or start attempts instead. The number depends on the document.
Combi gas: here E 122 H belongs to the flame and gas group (see E 121 H). The gas table in the CP plus manual also contains a row “E122H: lack of fuel”. Its content fits the diesel Combi.
E 212 H on the CP Plus: flame or gas
On the Combi gas, E 212 H belongs to the flame and gas group (see E 121 H). The 2016 CP plus manual also lists for 122 and 212: combustion air inlet or exhaust outlet blocked, gas pressure regulator faulty, electronics faulty. So check the flue cowl outside for snow, ice or leaves as well. If the fault remains, it is a case for Truma Service.
W 18 H and W 402 H: air overtemperature
The warm air cannot get away: not all warm air ducts connected, outlets or recirculation air intake blocked. According to Truma: connect the ducts and check them for kinks, clear outlets and intake, ventilate the installation space. On the Combi D, the equivalent warning is W 150 H.
W 412 H and W 42 H: window above the flue open
The window switch reports an open window above the flue cowl. According to the Truma FAQ: close and lock the window above or directly next to the wall cowl completely. On the Combi D, the same case appears in the CP plus manual as E 162 H and in the Truma FAQ only as “#162” without letters. Both mean the window switch.
W 408 H: mixed mode without gas
Combi E only. In mixed mode the gas supply is interrupted and the heater now runs on electricity only. According to Truma: restore the gas supply and switch to gas-only mode. The message then changes to E 507 H or E 516 H. Acknowledge that fault and then switch back to mixed mode.
E 621 H: room temperature sensor
The room temperature sensor or its cable is faulty. On first use, the code can flash because the heater is in the 15-minute lockout, says Truma. Wait, switch nothing off, then press briefly twice (backlight, then acknowledge). If E 621 H remains, the sensor is not connected, or sensor or cable is faulty. The Truma FAQ gives resistance values for checking: 16.2 kΩ at 15 °C, 12.6 kΩ at 20 °C, 10.0 kΩ at 25 °C. The notation varies: the FAQ calls 621 a warning in one place and E 621 H in another. The CP plus manual lists E 621 H.
E 607 H: acknowledged too often
The maximum number of fault resets has been reached: more than four within 15 minutes. The heater is locked. According to the CP plus manual: wait 15 minutes, then reset the fault. Remove the actual cause first, otherwise the fault comes back.
E 513 H, E 653 H and other codes that appear in no list
Not every code is in the Truma manuals. For E 513 H or E 653 H, for example, we found no explanation in Truma’s public documents. Truma publishes the codes you can check and fix yourself. According to the CP plus manual: if a code is not in the troubleshooting guide, or the fix does not help, contact Truma Service. Note the exact code with all its letters and your appliance: Combi gas or diesel, with or without E.
Table: Combi gas (Combi 4, 6, 4 E, 6 E)
Based on the troubleshooting guide in the Truma CP plus operating instructions. “Combi E only” refers to the versions with 230 V heating.
| Code | Meaning | What to do |
|---|---|---|
| W 17 H | Water overtemperature | Heater off, let it cool, fill the water container |
| W 18 H | Air overtemperature: not all warm air ducts connected, outlets or recirculation intake blocked | Connect and check the ducts, remove the blockage, ventilate the installation space |
| W 24 H | Imminent undervoltage, battery below 10.4 V | Check with engine running; charge battery, check contacts, replace an old battery |
| E 29 H | FrostControl heating element draws too much current | Replace the FrostControl heating element |
| W 42 H | Window above the flue open | Close the window |
| E 43 H | 12 V supply faulty (overvoltage) | Ensure 12 V under load at the appliance; disconnect charger and solar system as a test |
| W 45 H | 230 V supply faulty (Combi E only) | Ensure 230 V; have the fuse checked by a qualified person; reset the 230 V overheating protection |
| E 111 H | Fault in the electronics | Ensure 12 V under load; disconnect charger and solar system as a test |
| E 112 H, E 121 H, E 122 H, E 202 H, E 211 H, E 212 H | Flame out or not detected, flame unstable, gas supply interrupted | Ensure gas supply at the correct pressure (bottle, valves, regulator, flue) |
| W 255 H | No 12 V at the heater or no connection to the control panel | Ensure 12 V; check the control panel cable |
| W 301 H, W 417 H | Overvoltage | As for E 43 H |
| W 302 H, W 418 H | Undervoltage | Charge the battery, check contacts, replace an old battery |
| W 303 H, W 411 H | Imminent undervoltage, battery below 10.4 V | As for W 24 H |
| W 401 H | Hot water mode with empty water container | Heater off, let it cool, fill the water container |
| W 402 H | Air overtemperature | As for W 18 H |
| W 407 H | 230 V supply faulty (Combi E only) | Ensure 230 V; have the fuse checked by a qualified person |
| W 408 H | Gas supply interrupted in mixed mode (Combi E only) | Ensure gas; start in gas mode, acknowledge the fault, switch to mixed mode |
| W 412 H | Window above the flue open | Close the window |
| E 507 H, E 516 H, E 517 H | Gas supply interrupted | Ensure the gas supply, then acknowledge |
| E 607 H | More than four fault resets within 15 minutes, heater locked | Wait 15 minutes, reset the fault |
| E 621 H | Room temperature sensor or cable faulty | Check cable and connectors, replace the sensor |
| E 624 H | Short circuit in the FrostControl heating element | Replace the FrostControl heating element |
| E 632 H | 230 V overheating protection has tripped (Combi E only) | Reset the 230 V overheating protection (reset button, see Combi manual) |
Table: Combi D (diesel: D 4, D 6, D 4 E, D 6 E)
Based on the CP plus operating instructions and the Truma supplement “Combi D error codes”. Where the two contradict each other, the table says so.
| Code | Meaning | What to do |
|---|---|---|
| E 111 H | Room temperature sensor or cable faulty | Check cable and connectors |
| E 121 H | Interruption in the dosing pump, temperature switch has tripped | Clear the recirculation intake, ventilate the installation space; altitude kit above 1500 m; have cables and dosing pump checked |
| E 122 H | Lack of fuel: little in the tank, tank empty, vehicle on a slope | Fill the tank, fill the fuel line; ensure 12 V under load; altitude kit above 1500 m |
| E 131 H | No connection between heater and control panel | Restore the connection |
| E 132 H | Short circuit in the FrostControl heating element | Ensure 12 V under load, check for AC ripple |
| W 150 H | Warm air temperature exceeded | Check the warm air ducts, clear the recirculation intake |
| W 151 H | Water temperature exceeded in heating mode | Heater off, let it cool, fill the water container; check ducts and recirculation |
| E 152 H | Water temperature exceeded in hot water mode | Heater off, let it cool, fill the water container |
| W 160 H, W 161 H | Undervoltage. Depending on the document: the 2016 CP plus manual lists #161 as overvoltage above 16.4 V. | Ensure 12 V under load, charge or replace the battery; short term: switch off heavy loads or run the engine until the heater runs (approx. 4 minutes) |
| E 162 H | Window above the flue open (Truma FAQ: “#162”) | Close the window |
| W 163 H | One of the temperature switches has opened | Let the heater cool down; if it happens often, contact Truma Service |
| W 164 H | 230 V supply faulty (Combi D E) | Ensure 230 V; reset the 230 V overheating protection; have the fuse checked by a qualified person only |
| W 170 H | Imminent undervoltage. Depending on the document below 11.5 V (CP plus manual) or below 10.4 V (Truma FAQ) | As for W 160 H |
| W 255 H | No connection to the control panel, no 12 V or control panel cable faulty | Ensure 12 V; check the cable; have the appliance fuse checked by a qualified person |
| W 301 H, W 417 H, E 540 H | Overvoltage (above 16.4 V) | Check voltage sources |
| W 302 H, W 418 H, E 541 H | Undervoltage (below 10.0 V) | Charge the battery, replace if necessary; check with the engine running |
| W 303 H, W 411 H | Imminent undervoltage (below 10.8 V) | Charge the battery |
| W 423 H | Initial filling pending | Start the initial filling with a heating demand of 30 °C |
| W 424 H | Initial filling running, then normal operation at 30 °C | Do not switch the heater off, do not interrupt the power |
| E 560 H | Depending on the document: does not start, lock after the fifth acknowledgement (CP plus manual) or maximum start attempts reached, operating lock (supplement “Combi D error codes”) | Ensure the fuel supply, or contact Truma Service |
| E 561 H | Depending on the document the other way round: restart refused, operating lock (CP plus manual) or lock after five failed starts (supplement) | Contact Truma Service, or ensure the fuel supply |
| E 565 H | Heater does not start, flame repeatedly not detected | Ensure the fuel supply at the appliance inlet |
Table: older codes on the CP Plus, air conditioner and Vario Heat
Older CP plus manuals and the Truma FAQ write the Combi gas codes with a hash. The air conditioner (A) and the Vario Heat are added below.
| Code | Meaning | What to do |
|---|---|---|
| # 17 | Summer mode with empty water container | Heater off, let it cool, fill the water heater |
| # 18 | Warm air outlets or recirculation intake blocked | Check the openings, remove the blockage |
| # 21 | Room temperature sensor or cable faulty | Check the cable, measure the resistance, replace the sensor if necessary |
| # 24 | Imminent undervoltage below 10.4 V | Charge the battery |
| # 29 | Short circuit in the FrostControl heating element | Replace the heating element |
| # 42 | Window above the flue open | Close the window |
| # 43 / # 44 | Overvoltage above 16.4 V / undervoltage below 10.0 V | Check battery voltage and charger / charge the battery, replace if necessary |
| # 45 | No 230 V, 230 V fuse faulty or overheating protection tripped | Depending on the document: contact Truma Service (2016 manual) or reset the overheating protection yourself (Truma FAQ) |
| # 112, # 121, # 202, # 211 | Gas closed, regulator iced up or too much butane | Open the valves, regulator heater (EisEx), use propane |
| # 122, # 212 | Combustion air or exhaust blocked, regulator or electronics faulty | Check the openings; have the regulator checked; Truma Service |
| # 255 | No 12 V or no connection | Ensure 12 V, restore the connection |
| E 8 A, W 8 A | Air conditioner: IR receiver unplugged or cable break | Check the IR receiver connector |
| E 17 A, W 17 A | Air conditioner: voltage drop on the 230 V supply | Check the 230 V supply |
| E 2 H, E 16 H | Vario Heat: flame not detected (bottle empty or closed, regulator iced up, butane, flue blocked) | Change the bottle, open the valves, EisEx, propane, check the openings |
| W 25 H / W 26 H | Vario Heat: overvoltage above 16.4 V / undervoltage below 10 V | Check battery voltage and charger / charge the battery |
| W 27 H | Vario Heat: warm air or recirculation blocked, end pieces closed | Remove the blockage, open the end pieces |
| W 28 H | Vario Heat: window above the flue open | Close the window |
| W 29 H | Vario Heat: imminent undervoltage below 10.4 V | Charge the battery |
| W 101 E to W 104 E, W 255 E | Vario Heat, E-Kit: voltage, warm air blocked, no 230 V, no connection | See the Vario Heat manual |
Truma iNet X Panel: plain text instead of a code list
The iNet X Panel operating instructions contain no code list. According to Truma, the panel shows faults of connected appliances directly and suggests solutions.
| Display | Meaning | What to do |
|---|---|---|
| Message in plain text | A connected appliance reports a fault | Follow the instructions on the display |
| Code via “More info …” or main menu → “>” | The error code Truma needs for a service case | Note down the code |
| Resetting the fault | The cause has been removed | Acknowledge the fault on the control panel |
| W 434 H (CombiNeo only) | No air bubble left in the water container, FrostControl opens unintentionally several times | Pump off, open FrostControl for approx. 15 seconds (approx. 2 litres of water), close, pump on, open the hot tap if necessary until the water runs free of air |
Truma does not say explicitly whether a code on the iNet X Panel means the same as in the CP Plus tables. The plain text on the panel is what counts.
What CampMatic shows when there is a fault
With CampMatic you can see in the app, from wherever you are, that the heater is in fault. What else you learn depends on the control panel:
- With a CP Plus (CampMatic for Truma CP Plus): the app shows the status “Error”, without a code and without an explanation. In the Telegram bot, the /status command returns the code number, but without letters, for example 517. Knowing whether your Combi runs on gas or diesel, you can find the number in the tables above.
- With an iNet X Panel (CampMatic for Truma iNet X): the app shows a card with the code, for example W 164 H, plus the plain text and possible remedies under “What to do”. So you know what the code means while you are still on the road.
In both cases you can only acknowledge a fault on the control panel, not from the app. CampMatic for Truma CP Plus requires a CP Plus with firmware C4 or F4, or P5 on the Vario Heat. You can see the version on the CP Plus under Settings → INIT.
Safety: what you may do yourself
- According to Truma, you may only fix faults yourself if the fix is described in the troubleshooting guide of the operating instructions. Everything else belongs with a qualified person or Truma Service.
- The gas system, gas pressure regulator and 230 V fuses are a job for a qualified workshop.
- If you smell gas, according to Truma: no ignition sources (naked flames, electrical switches, mobile phone, engine, smoking). Open windows and doors, get everyone out, close the gas bottles or shut off the gas from outside. Use the gas system again only after a qualified person has checked and repaired it.
- Never operate gas appliances while refuelling, in multi-storey car parks, garages or on ferries. Truma points out explicitly that they must not be switched on there by remote control or app either.
- Combi D: if there is heavy smoke at the flue for more than one minute after starting, Truma says to stop using the appliance and contact customer service.
→ CampMatic for Truma CP Plus · WiFi — €149
→ CampMatic for Truma CP Plus · 4G — €209
Further reading: