Truma Combi flashing red, yellow or green: what the light means

Reading time: 7 min
CampMatic

This article is also available in: Deutsch · Français · Español · Italiano · Polski · Čeština · Svenska · Nederlands

Truma Combi flashing red, yellow or green: what the light means

An LED is flashing on your Truma Combi control panel, yellow or red, once or up to nine times. Truma explains what it means in the manual for the analogue CP classic panel. Here are the meanings as tables, plus what the digital CP Plus shows instead.

Quick answer

  • Green on: the heater is in operation.
  • Yellow on: the hot water is heating up. Yellow flashing: warning. The number of flashes tells you the cause.
  • Red flashing or on: fault.
  • These LEDs are on the analogue CP classic control panel. The digital CP Plus shows codes such as W 18 H or E 517 H and symbols on its display instead.

Yellow or orange?

Truma calls this LED yellow in its manuals. Many people describe the colour as orange. An LED that Truma calls orange does not appear in the manuals for the Combi control panels. If a light in that shade is on or flashing, use the tables to check whether the pattern matches the yellow LED.

How to count the flashes

According to Truma, the LED flashes 0.5 seconds on, 0.5 seconds off, then pauses for 5 seconds. Count the flashes between two pauses, ideally twice.

CP classic on the Combi gas

The CP classic has three LEDs: green for operation, yellow for hot water and warnings, red for faults. According to the Truma manual:

DisplayCauseWhat to do
No LED although switched on and power presentAutomatic restart blocked, e.g. after a power interruptionSwitch off, wait 5 seconds, switch on again
No LED after switching onNo operating voltage, appliance or vehicle fuse faultyCheck 12 V, plugs and fuses
Green on, heater not runningSet temperature lower than room temperatureSet a higher temperature
Green on, yellow flashes 1× (heater keeps running)Imminent undervoltage below 10.4 VCharge the battery
Yellow flashes 2× (heater off)Undervoltage below 10.0 V or overvoltage above 16.4 VCharge or replace the battery, or check the charger
Yellow flashes 3×Window above the flue openClose the window; heating then resumes
Yellow flashes 4× (fault after some time)Summer mode with empty water container, warm air outlets or recirculation intake blockedSwitch off, let it cool, fill the water heater; clear the openings
Yellow flashes 5×Room temperature sensor or cable faultyTruma Service
Yellow flashes 7×Control panel or panel cable faultyTruma Service
Yellow flashes 8×Short circuit in the FrostControl heating elementUnplug at the control unit, replace the heating element
Yellow flashes 9× (approx. 30 seconds after switching on or after a longer run)Gas bottle or quick-closing valve closed, bottle empty, regulator iced up, too much butaneOpen the valves, change the bottle, regulator heater (EisEx), use propane
Red flashes 1× to 8×Fault in the heaterTruma Service; blink code of the red LED on the heater electronics (see below)
Green and red on after switching onElectronics faultyTruma Service
Green stays on after switching offAfter-run to bring the temperature down, 5 minutes at mostNot a fault

CP classic on the Combi D (diesel)

On the diesel Combi, some flash patterns mean something different. According to the Truma manual:

DisplayCauseWhat to do
No LEDNo voltage or fuse faultyCheck voltage and fuses
Green on, heater not runningSet temperature too lowSet it higher
Green flashes fast (5 Hz) after switching offAfter-run, 5 minutes at mostNot a fault
Yellow flashes 1×Imminent undervoltage below 11.5 VSave power, charge the battery
Yellow flashes 2×Undervoltage below 10.2 V or overvoltage above 16.4 V; Combi D 6 E only: no 230 V, 230 V fuse faulty or overheating protection trippedCheck battery, charger and 230 V; reset the overheating protection (reset button); fuse only by a qualified person
Yellow flashes 3×Window above the flue openClose the window
Yellow flashes 4×Warm air or water temperature exceededCheck warm air ducts, outlets and recirculation intake; fill the water heater
Yellow flashes 5×Room temperature sensor or cable faultyTruma Service
Yellow flashes 6×Water temperature exceeded in summer modeFill the water heater
Yellow flashes 7×Control panel or cable faultyTruma Service
Yellow flashes 8×Short circuit in the FrostControl heating elementReplace the heating element
Red flashes 6×Lack of fuel: tank almost empty or vehicle on a slopeRefuel, fill the fuel line as for first use
Red flashes (other than 6×) or red onFault in the heaterTruma Service

Yellow LED on the energy selector (CP E classic, Combi D E)

The diesel Combi E has a second switch on the panel for the energy type, with its own yellow LED. According to Truma:

  • Yellow LED on the energy selector on: operation on 230 V.
  • Goes out, panel flashes yellow or red: fault in electric mode.
  • Mixed mode, goes out, yellow flashes 2×: no 230 V. The heater switches to diesel and returns to mixed mode by itself once 230 V is back.
  • Mixed mode, stays on, red or yellow flashes: combustion fault. The heater switches to electric. It returns to mixed mode only after the cause is removed and you switch off and on at the panel.

According to Truma, the CP classic is not intended for the gas Combi E, which uses a digital control panel.

Vario Heat with CP classic

On the Vario Heat, the red LED means something else. According to Truma: red flashes 1× = flame or gas (bottle empty or closed, regulator iced up, butane, flue blocked); 2× = heater fault, Truma Service; green on and red 3× = undervoltage or overvoltage; 4× = window above the flue open; 5× = warm air or recirculation blocked; 6× = motor wear limit soon reached, Truma Service. If no LED is on although there is power: switch off, wait 5 seconds, switch on again.

Common questions in brief

The red light stays on

On the Combi D, a steady red light means a fault in the heater, according to Truma: a case for Truma Service. On the Combi gas, Truma describes “green and red on after switching on”: electronics faulty, also for Truma Service.

The yellow light is flashing

That is a warning. Count the flashes between the pauses and check the table for your Combi. On gas and diesel alike, one flash means imminent undervoltage and three mean the window above the flue is open.

Combi 4 flashing green

Truma only documents green flashing for the Combi D: after switching off, green flashes fast during the after-run, for 5 minutes at most. On the Combi gas, green stays on during the after-run. Truma describes no green flashing for the Combi 4 gas. The after-run is intended: according to the Truma FAQ, it protects the Combi from overheating caused by heat build-up and cannot be switched off.

Red LED on the heater electronics: the blink code for the service team

If the red LED on the panel flashes 1× to 8×, Truma refers to a second red LED on the heater’s electronics. According to the Truma service blog, its blink code is like Morse code: short and long signals in a set order. Combis built before 06/2018 use eight signals, later ones ten. Truma asks for the code by video or phone. There is no public translation table. Leave work on the heater itself to a qualified person.

What the CP Plus shows instead of LEDs

The digital CP Plus reports warnings and faults as a code on the display. The meanings are in the list of Truma error codes. According to Truma’s manuals, also:

  • Warning symbol (triangle) with a W code: warning, the heater keeps running. The symbol goes out by itself once the value is back in range.
  • E code: fault. Remove the cause, then acknowledge with the rotary/push knob.
  • Code flashing: the heater is in a lockout of up to 15 minutes. Only then can the fault be reset.
  • Hot water symbol flashing: the target water temperature has not been reached yet. Not a fault.
  • Heating symbol flashing: according to the 2016 CP plus manual and the Vario Heat manual, until the room temperature is reached. The 2022 edition no longer mentions this. Not a fault.
  • Timer symbol flashing: a timer is programmed and active.

Acknowledging a fault, and why RESET → PR SET is the wrong tool: Truma Combi reset: clearing faults, RESET on the CP Plus, reset button.

Other Truma LEDs: iNet Box and iNet X Panel

  • Truma iNet Box: according to the Truma FAQ, the blue LED flashes until the box is connected to the Truma App, the green one until it is ready for operation, and the red one until the GSM function is set up.
  • Truma iNet X Panel: two LEDs on the back show the operating status once 12 V is present; installed, they are only visible through a gap at the side. Truma has not published what the colours mean. The panel shows faults as plain text.

And with CampMatic?

CampMatic requires a CP Plus with firmware C4 or F4 (P5 on the Vario Heat) or a Truma iNet X Panel. An analogue CP classic is not enough. With CampMatic for Truma CP Plus you can see in the app, wherever you are, that the heater is in fault: the app shows the status “Error”. With CampMatic for Truma iNet X the app shows a card with the code, the plain text and “What to do”. In both cases you can only acknowledge the fault on the control panel.