You will find the software version of your Truma CP Plus on the panel under Settings → INIT. The version number comes first: a letter followed by three groups of digits. The letter tells you which device it refers to, the digits give the software level.
Here is how to read the display, which version you need for app control, who updates the software and what helps when the CP Plus only shows the time or will not switch on.
At a glance
- Reading the version: Settings → INIT. The first entry is the version number.
- The letter matters: C = CP Plus, F = CP Plus CI-BUS, P = CP Plus VarioHeat, H = heater, T = iNet Box.
- For CampMatic: C4.xx.xx or F4.xx.xx, P5.xx.xx on the Vario Heat. With C3, values can only be read; C5 does not work.
- Updates: only Truma installs CP Plus software, either when you send the panel in or via a mobile service technician.
- Only the time on the display: usually a reset was run without a connection to the heater. Fix the cause, then initialise again.
How to read the software version on the CP Plus
- Tap the rotary push button to switch the CP Plus on.
- Turn the button to Settings and press to confirm.
- Select INIT.
- The first entry is the version number, for example C4.02.01. Write it down.
Depending on the equipment, further identifiers follow. Truma gives this example for one installation: C4.02.01 for the CP Plus, H1.02.00 for the Combi and T2.09.00 for the iNet Box.
Important: to read the version, looking is enough. You do not need a reset (PR SET). PR SET returns the panel to its default settings, deletes all your settings and searches for connected devices again. If the heater cannot be reached at that moment, it is missing from the menu afterwards (see below).
What the letters mean
The display shows a letter for the device and the version number after it. According to the Truma manual:
| Code | Device |
|---|---|
| C | Truma CP Plus control panel |
| F | Truma CP Plus CI-BUS control panel |
| P | Truma CP Plus VarioHeat control panel |
| H | Heater |
| T | Truma iNet Box |
| A | Air conditioning system |
So "F4" means the CI-BUS variant of the CP Plus, version 4. This variant is only fitted at the factory. If an external control unit operates the heater via the CI-BUS, the display shows "CI". "P5" means CP Plus VarioHeat, version 5.
Which version do you need for CampMatic?
CampMatic for Truma CP Plus sits on the heater's bus, where the iNet Box would otherwise be. Whether the box can control the heater depends on the CP Plus version:
| Your heater | Matching CP Plus version |
|---|---|
| Truma Combi — gas, diesel, electric | C4.xx.xx or F4.xx.xx |
| Truma Vario Heat, including with E-Kit | P5.xx.xx |
For other versions:
- C3.xx.xx: CampMatic can read values but cannot control the heater.
- C5.xx.xx: does not work.
- F5.xx.xx: not yet tested by us. Ask us before you order.
The fact that your iNet Box works, or that the panel says "iNet ready", is no guarantee. The iNet Box already copes with C3. Only the version number counts. If you are unsure, send it to us at info@campmatic.de and we will tell you in advance whether it fits.
Do you have a Truma iNet X Panel instead of a CP Plus? Then there is no firmware requirement. There is a separate box for it: CampMatic for Truma iNet X.
Can you update the CP Plus software?
Not yourself. According to Truma's service team, CP Plus software is installed by Truma only. You either send the panel in, or a Truma mobile service technician does it. Truma does not mention updates by owners or dealers.
Truma has also stated that the software only needs to be reinstalled when error messages occur. New display elements cannot be added by software anyway, because the symbols are fixed in the display.
Two things are often confused:
- iNet Box update in the Truma app: it concerns the iNet Box firmware.
- From C3 to C4: an upgrade to C4 is possible. It is done by Truma's service team; ask them directly how it works and on what terms.
- Tip from our customers: many have bought a used CP Plus with C4 instead, for example on eBay for around €100. When buying, check that the version is C4.xx.xx or F4.xx.xx (not C5), ideally with a photo from the seller. After swapping, run the device search on the new panel once (RESET → PR SET) so it finds the heater.
CP Plus only shows the time
First of all: in standby, the display alternates between the time and the set room temperature, according to the manual. That is normal.
If, on the other hand, only the time and the setup symbol remain and the heater menu is missing, Truma says this is usually caused by a reset that ran while there was no connection to the heater. The CP Plus simply did not find the heater.
Typical reasons for the missing connection:
- No 12 V at the heater: the fuse in the electrical block or on the heater's control board has blown, or the heater's power supply is switched off at the vehicle's main panel.
- TIN cable not seated: check the plugs on the CP Plus and on the heater.
- Combi D with a long cable: more than 12 m of TIN cable is too much. Truma offers a coupler for the control panel cable.
What to do: fix the cause first, then run RESET → PR SET on the CP Plus again. The panel searches for the connected devices and registers them afresh. Your settings are lost in the process, so set the temperature and timer again afterwards. Truma recommends connecting the CP Plus and heater to an unswitched permanent positive supply.
After a power interruption, by the way, you only need to set the time and the time switch again. All other settings are kept.
CP Plus will not switch on
Start with the operation, because that is often where the answer lies:
- Switching on: briefly tap the rotary push button.
- Switching off: press for more than 4 seconds. With an iNet Box, "APP" appears after 2 seconds and "OFF" after another 2. Switching off can be delayed by a few minutes because of internal run-on.
- APP mode: if the display shows "APP", the devices are in standby. There is no heating, no hot water and no time switch. The mode ends as soon as new values arrive via the app or you press the button.
If the CP Plus does not respond at all, or the heater will not start, check:
- Voltage: the CP Plus needs 8 to 16.5 V from an unswitched permanent positive supply with a 1 A fuse. The heater and the CP Plus must be on the same circuit.
- Flashing error code: if 507, 516, 517 or 621 is flashing, a 15-minute lockout is running. Do not switch off or disconnect the power during that time. Switching off and on does not clear the fault, it restarts the lockout.
- Heater supply: check 12 V, gas or fuel, and the TIN cable. If that does not help, take the system to a specialist workshop.
Frequently asked questions
Where do I find the software version on a Truma CP Plus?
Under Settings → INIT. The first entry is the version number, for example C4.02.01.
Can I update the CP Plus software myself?
No. Only Truma installs the software, when you send the panel in or via a mobile service technician.
What does F4 mean on a CP Plus?
F stands for the CI-BUS variant of the CP Plus, 4 for the version. For CampMatic, F4.xx.xx fits just as C4.xx.xx does.
My CP Plus only shows the time. What should I do?
Usually a reset ran without a connection to the heater. Check the heater's 12 V supply and TIN cable, then run RESET → PR SET again.
I have an iNet X Panel. Which version do I need?
None in particular. For the iNet X Panel there is CampMatic for Truma iNet X, with no firmware requirement.
→ CampMatic for Truma CP Plus · WiFi — €149
→ CampMatic for Truma CP Plus · 4G — €209
Further reading: